ANALISIS PENERAPAN SISTEM TANGGAP DARURAT KEBAKARAN DI PT X

Zaki Muthahhari Lubis, Juli Soemirat, Didin Agustian Permadi

Abstract


Wildfire is an uncontrolled fire that can occur because of the reaction of 3 elements, namely combustible material, heat source, and oxygen. This fire has the potential to occur in industries that have these three elements, the impact of which can result in losses for company assets, including facilities and workers. Therefore, fires are one of the most common types of emergencies in the industry. For industries that have this potential hazard, it is necessary to have a fire emergency response system to prepare technical things that must be done when the fire occurs. PT X is one of the industries in Indonesia engaged in electronics that has the potential for fire hazards in 4 work areas, namely the office area, electronic production, mechanics, and solar modules. Thus, it is necessary to evaluate the fire emergency response system in PT X's work environment which includes emergency response management, active protection facilities, and life-saving facilities. The existing conditions of each component are compared with several applicable standards, namely NFPA 10, 13, 14, 72, 101, Kepmen PU No. 11/2000, and Permen PU No. 26/2008. The results showed that the application of the fire emergency response system at PT X on the basis of applicable standards was 57.75%. This figure shows the level of reliability with a value of Less (K) because there are some components for which the application does not yet exist and for some existing components, it is not in accordance with applicable standards.

 

Keyword: Fire, Industry, emergency response system


Full Text:

Untitled

References


Annilawati, N., Fitri, A. M. (2019). Analisis Sistem Tanggap Darurat Bencana Rumah Sakit X di Jakarta Selatan Tahun 2018. Jurnal Ilmiah Kesehatan Masyarakat Universitas Pembangunan Nasional Veteran Jakarta, 11 (2).

Ashary, I. Z., Kurniawan, B., dan Widjasena, B. (2015). Analisis Sistem Tanggap Darurat Kebakaran di Area Produksi Industri Kimia PT X Tahun 2015. Jurnal Kesehatan Masyarakat Universitas Diponegoro, 3 (3).

Badan Litbang PU Departemen Pekerjaan Umum (2005). Pemeriksaan Keselamatan Kebakaran Bangunan Gedung. Jakarta: Departemen Pekerjaan Umum.

Faeliskah, Kurniawan, B., Suroto. (2017). Analisis Implementasi Sistem Tanggap Darurat Berdasarkan OHSAS 180001:2007 Klausul 4.4.7 di PT X Kalimantan Selatan. Jurnal Kesehatan Masyarakat Universitas Diponegoro, 5 (1).

Fitri, M. E., dan Sufianto, H. (2018). Studi Tingkat Keandalan Keselamatan Kebakaran Pasar Andir Kota Bandung. Jurnal Arsitektur Universitas Brawijaya, 6 (3).

Handayana, S. H., Suroto, dan Kurniawan, B. (2016). Analisis Manajemen Pelaksanaan Pada Kesiapsiagaan dan Tanggap Darurat di Gedung Perkantoran X. Jurnal Kesehatan Masyarakat Universitas Diponegoro, 4 (1).

Hesna, Y., Hidayat, B., dan Suwanda, S. (2009). Evaluasi Penerapan Sistem Keselamatan Kebakaran Pada Bangunan Gedung Rumah Sakit DR. M. Djamil Padang. Jurnal Rekayasa Sipil Universitas Andalas, 5 (2).

Keputusan Menteri Negara Pekerjaan Umum No. 11/KPTS/2000 tentang Ketentuan Teknis Manajemen Penanggulangan Kebakaran di Perkotaan.

Keputusan Menteri Tenaga Kerja Republik Indonesia No. KEP./186/MEN/1999 tentang Unit Penanggulangan Kebakaran di Tempat Kerja.

Kowara, A. R., dan Martiana, T. (2017). Analisis Sistem Proteksi Kebakaran Sebagai Upaya Pencegahan dan Penanggulangan Kebakaran. Jurnal Manajemen Kesehatan Yayasan RS Dr. Soetomo, 3 (1).

Mufilda, M. R., Martiana, T. (2019). Sistem Tanggap Darurat Kebakaran di Gedung Administrasi Perusahaan Listrik. The Indonesian Journal of Occupational Safety and Health, 8 (1).

National Fire Protection Association (NFPA) 10. (1995). Standard for Portable Fire Extinguisher. United State of America: National Fire Protection Association.

National Fire Protection Association (NFPA) 101. (1995). Life Safety Code. United State of America: National Fire Protection Association.

National Fire Protection Association (NFPA) 13. (1995). Installation of Sprinkler System. United State of America: National Fire Protection Association.

National Fire Protection Association (NFPA) 14. (1995). Standard for Installation of Standpipes, Private Hydrant, and Hose System. United State of America: National Fire Protection Association.

National Fire Protection Association (NFPA) 72. (1995). National Fire Alarm Code. United State of America: National Fire Protection Association.

OSHA. (1984). Accident Prevention. United State of America: OSHA.

Peraturan Menteri Pekerjaan Umum No. 26/PRT/M/2008 tentang Persyaratan Teknis Sistem Proteksi Kebakaran Pada Bangunan Gedung dan Lingkungan.

Peraturan Menteri Tenaga Kerja dan Transmigrasi No. PER.04/MEN/1980 tentang Syarat-Syarat Pemasangan dan Pemeliharaan Alat Pemadam Api Ringan.

Pratiwi, M. A., Lestari, F., dan Ridwansyah. (2013). Analisis Implementasi Sistem Tanggap Darurat Berdasarkan Asosiasi Perlindungan Kebakaran Nasional 1600. Jurnal Kesehatan Masyarakat Nasional Universitas Indonesia, 7 (10).

Sambada, G. H., Kurniawan, B., dan Suroto. (2016). Analisis Sistem Tanggap Darurat Kebakaran di Container Yard 02 Terminal Petikemas PT Pelabuhan Indonesia III (Persero) Semarang Tahun 2016. Jurnal Kesehatan Masyarakat Universitas Diponegoro, 4 (4).

Ramli, S. (2010). Petunjuk Praktis Manajemen Kebakaran. Jakarta: Dian Rakyat.

Salami, I., dkk. (2015). Kesehatan dan Keselamatan Lingkungan Kerja. Yogyakarta: Gadjah Mada University Press.




DOI: https://doi.org/10.31848/ejtl.v2i2.398

Refbacks

  • There are currently no refbacks.